www.bualotech.comUser ManualGigabit Managed Switch with PoE+BSL-PS-G2108MBSL-PS-G2116M
Chapter 1 Product Overview- 9 -Cooling FanA fan for cooling the power supply is installed in the rear panel of the switch. If the fan stops, a buzzer
- 10 -Chapter 1 Product OverviewPoE PlusThis switch supports 802.3at PoE Plus (Power over Ethernet Plus). PoE supplies power to network devices over
- 11 -Chapter 2 - CongurationSettingsThis chapter describes how to use the web-based conguration interface to congure the switch and monitor the ne
- 12 -Chapter 2 Conguration7Click OK.If the IP Address screen appears, select “Get IP address from DHCP” or set the IP address manually and click Ne
Chapter 2 Conguration- 13 -HomeWhen you connect to the switch with your Web browser, the home page is displayed. The menu tree is displayed on the l
- 14 -Chapter 2 CongurationMainSystem InfoYou can verify settings and the status of the switch here.---> System InfoParameter MeaningProduct Name
Chapter 2 Conguration- 15 -BasicSystemThese settings specify information for identifying the switch.---> Basic > SystemParameter MeaningName T
- 16 -Chapter 2 CongurationMAC Address FilteringThe ltering settings are made by MAC address.---> Basic > MAC Address FilteringParameter Mean
Chapter 2 Conguration- 17 -Flow Control StatusThis displays the Flow Control Status.---> Basic > Flow Control > StatusParameter MeaningName
- 18 -Chapter 2 CongurationFlow ControlThese settings are used to congure the ow control of each port.---> Basic > Flow Control > Flow Co
- 1 -ContentsChapter 1 - Product Overview ...4Features ...
Chapter 2 Conguration- 19 -must also support the function for this to take eect.• The Auto-MDI-X function is disabled if the rate and duplex mode
- 20 -Chapter 2 CongurationDate and TimeThese settings are used to congure SNTP (Simple Network Time Protocol) settings.---> Basic > Date and
Chapter 2 Conguration- 21 -PoE StatusThese indicators show the PoE status.---> Basic > PoE > StatusParameter MeaningPower Maximum: This ind
- 22 -Chapter 2 CongurationPort PoE SettingsThese are used to make the PoE settings.---> Basic > PoE > SettingsParameter MeaningCurrent Pro
Chapter 2 Conguration- 23 -Parameter MeaningHigh Power If enabled, the proprietary Bualo high-power function, an extension of the IEEE 802.3af stan
- 24 -Chapter 2 CongurationPoE ProlesThis is used to set the power-saving proler.The power-saving proler is a function used to dynamically or man
Chapter 2 Conguration- 25 -Parameter MeaningSchedule Manual: The prole is switched manually. Automatic: The prole is switched automatically.Curren
- 26 -Chapter 2 Conguration---> Basic > Power Saving > Power Proles > Edit ProlesParameter MeaningFinished Editing Click to return to
Chapter 2 Conguration- 27 ----> Basic > Power Saving > Power Proles > Edit ScheduleParameter MeaningFinished Editing Click to return to
- 28 -Chapter 2 CongurationParameter MeaningProle Selection Specify the prole selection method.Use prole below:This species by the prole.Copy p
- 2 -Authentication Servers ... 34RADIUS ...
Chapter 2 Conguration- 29 -AdvancedVLANsThese settings are used to view the current VLAN settings and create new VLANs.---> Advanced > VLANs &
- 30 -Chapter 2 CongurationParameter MeaningVLANs This displays the current VLAN conguration and PVIDs (Port VLAN IDs).The information displayed fo
Chapter 2 Conguration- 31 -than 2.)• In Privacy Separator, the switch’s management interface can only be accessed from Uplink ports. If the port co
- 32 -Chapter 2 CongurationQoS StatusThese settings are used to congure priority levels.---> Advanced > QoS > StatusParameter MeaningQoS E
Chapter 2 Conguration- 33 -QoS MappingThese settings are used to congure the mapping of ToS, CoS, and port-based priority levels.---> Advanced &
- 34 -Chapter 2 CongurationAuthentication ServersThis displays the status of the authentication server and port authentication.---> Advanced >
Chapter 2 Conguration- 35 -RADIUSThese settings are used to congure the authentication server.---> Advanced > Authentication > RADIUSParam
- 36 -Chapter 2 CongurationPort AuthenticationThese settings are used to congure 802.1X authentication for each port.A separate authentication serv
Chapter 2 Conguration- 37 -Parameter MeaningEAP Extensions Insert a check mark here to disable the authentication function for all setting ports or
- 38 -Chapter 2 CongurationPassword AuthenticationThis is used to make the password authentication settings.A separate authentication server is requ
- 3 -Appendix ...60Default Conguration Settings ...
Chapter 2 Conguration- 39 -Parameter MeaningText Text displayed in password authentication page.Footer Footer displayed in password authentication p
- 40 -Chapter 2 CongurationPort TrunkingThese settings are used to congure port trunking.---> Advanced > Port TrunkingParameter MeaningLACP S
Chapter 2 Conguration- 41 -• If LACP or trunk is set, the ports of the same trunk group must be on the same VLAN.• If changing the VLAN, the setti
- 42 -Chapter 2 CongurationParameter MeaningDLFRate LimitThe rate of DLFs (destination lookup failure unicasts) that may be allowed to pass.When the
Chapter 2 Conguration- 43 -BPDU ForwardingThese settings are used to congure BPDU.---> Advanced > BPDU ForwardingParameter MeaningBPDU Forwar
- 44 -Chapter 2 CongurationLoop PreventionCongure loop prevention settings here.---> Advanced > Loop Prevention
Chapter 2 Conguration- 45 -Parameter MeaningAction when loops detected This sets operation when a loop is detected.Ignore :No operation is performed
- 46 -Chapter 2 CongurationLoop prevention Spanning treeOperation when loop detectedThis disables the port for a preset length of time.After the pre
Chapter 2 Conguration- 47 -Parameter MeaningUpdate from PC: Specify a rmware le stored on a computer.USB Device: Specify a rmware le stored on
- 48 -Chapter 2 CongurationParameter MeaningSave to PC: Click Save to save the settings.USB Device: Specify the name of a le saved on the USB dev
- 4 -Chapter 1 - Product OverviewFeaturesModels AvailableBSL-PS-G2116M• 16 1000BASE-T/100BASE-TX/10BASE-T ports.• 2 SFP ports. (SFP ports are used e
Chapter 2 Conguration- 49 -InitializeThis is used to initialize the settings and reboot the switch.---> Management > InitializeParameter Meani
- 50 -Chapter 2 CongurationParameter MeaningMAC Address Table (Port Order) This displays the MAC address table in port order.Click Refresh to update
Chapter 2 Conguration- 51 -StatisticsThis displays statistics on the switch.---> Management > StatisticsParameter MeaningName Name of the port
- 52 -Chapter 2 Conguration---> Management > Statistics > DetailsParameter MeaningReceived Octets Data octets received.Received Unicast Uni
Chapter 2 Conguration- 53 -LogsThis displays the switch’s log information.---> Management > LogsParameter MeaningSort Select the type of log m
- 54 -Chapter 2 CongurationParameter MeaningEnable Enables transfer of logs to a Syslog server.IP Address Specify the IP address of the Syslog serve
Chapter 2 Conguration- 55 -Parameter MeaningBoot Mode The settings le is read from a USB device when booting.When the boot settings are set to read
- 56 -Chapter 2 CongurationPingThis is used to perform Ping (response conrmation) tests.---> Management > PingParameter MeaningDestination IP
Chapter 2 Conguration- 57 -SupportSupportThis displays Bualo’s website.---> SupportParameter MeaningSupport This is a link to Bualo’s website,
- 58 -Chapter 3 - TroubleshootingPower LED is not litCheck that the switch and the power outlet are connected by the power cable.Link LED is not lit•
Chapter 1 Product Overview- 5 -• RMON group 1, 2, 3 and 9 support (Statistics, History, Alarm, and Event)• The device can be congured by Web (HTTP
Chapter 3 Troubleshooting- 59 -Power ProblemsIf the power LED is not lit when power is connected, this could be a problem with the power outlet, powe
- 60 -AppendixDefault Conguration SettingsFeature Parameter Default SettingSystem Name BSL + switch’s MAC AddressIP Address 192.168.1.254Subnet Mask
Appendix- 61 -Feature Parameter Default SettingQoS Status QoS Settings QoS: OQueue: StrictPriority NoneQoS Mapping Port Priority LowCoS Mapping LowR
- 62 -AppendixTwisted Pair Cable and Port SpecicationsA two-pair twisted pair cable is required for 1000BASE-T, 100BASE-TX and 10BASE-T connections.
Appendix- 63 -1000BASE-T Port SpecicationsThe switch supports Auto-MDIX on all 1000BASE-T ports. You can use straight cables in all network connectio
- 1 -CAUTION: Please read and observe the following general product safety information guidelines.The following safety guidelines and precautions will
- 2 -Do not expose the product to extremely hot or extremely cold temperatures, or place it near radiators, electric heaters, or other heat sources.Ar
- 3 -Product EnvironmentIn order to minimize the risk of electrical shock, re, and damage to the Bualo product and related computer and other electr
- 6 -Chapter 1 Product OverviewPoE (Power over Ethernet)• Compliant with IEEE 802.3at and IEEE 802.3af• Overcurrent protection function compliant w
Chapter 1 Product Overview- 7 -BSL-PS-G2108MCooling fanPower connectorPower cable attachment band12351. IndicatorsIndicators are located on the front
- 8 -Chapter 1 Product OverviewLED StatusPoE (green or orange) On (green): PoE is being suppliedOn (orange): The load exceeds the specied value or